High Power Laser Theraphy

High Power Laser Theraphy

Price: Call Us

Categories: 

HighPowerLaser_BipowerLux 6W

1

Bipower Lux combines 2 wavelengths, 810+980 nm, to be used in combined therapy, and gets the best of their main therapeutic actions:

810 nm wavelength has a high depth of penetration in the tissues and gives an excellent biostimulating effect.

980 nm wavelength has a high level of absorption in the fluids and provides a high analgesic effect. Bipower Lux is recommended for superficial pathologies in general medicine and dermatology and for orthopaedic and sport medicine pathologies (contusions, bursitis, tendinitis, etc.). It has a high biostimulating effect because it covers the whole therapeutic window of high power therapeutic lasers (HPLS –>high power laser system) with a very high output power (up to 12W).

TECHNICAL SPECIFICATION:

  • Power supply : 230 Vca, 50-60 Hz ± 10%
  • Maximum main power absoption : 75VA
  • Double delay type (T) mains : 230 V ac 630mA-T-5×20 mm
  • Backlit LCd display to view and check theoperating parameters : Graphic colour LCD8″ T ouch screen
  • Maximum power : 12 W
  • Configuration of the laser probe : Integral connection with the machine
  • Emmision wavelength laser diode : 810+980 nm
  • Laser classification : 4
  • DNRO(m) : 2,986
  • Emmision frequency : 100 – 10.000 Hz
  • Pulsed mode : 10 – 100%
  • Classification according toDirective 93/42/EEC : IIB
  • Output channels : 1
  • Insulation class/part applied in accordance-
  • with EN60601-1 : I/BF Type
  • Stored protocols : 32
  • Storable programs on the internal memory : 200
  • Storable programs on the USB : 4 GB
  • Weight : 4,90 Kg
  • Size : 39 x 17,5 x 28 cm

HighPowerLaser_BipowerLux 8W

1

Bipower Lux combines 2 wavelengths, 810+980 nm, to be used in combined therapy, and gets the best of their main therapeutic actions:

810 nm wavelength has a high depth of penetration in the tissues and gives an excellent biostimulating effect.

980 nm wavelength has a high level of absorption in the fluids and provides a high analgesic effect.
Bipower Lux is recommended for superficial pathologies in general medicine and dermatology and for orthopaedic and sport medicine pathologies (contusions, bursitis, tendinitis, etc.). It has a high biostimulating effect because it covers the whole therapeutic window of high power therapeutic lasers (HPLS –>high power laser system) with a very high output power (up to 12W).

TECHNICAL SPECIFICATION:

  • Power supply : 230 Vca, 50-60 Hz ± 10%
  • Maximum main power absoption : 75VA
  • Double delay type (T) mains : 230 V ac 630mA-T-5×20 mm
  • Backlit LCd display to view and check-
  • the operating parameters : Graphic colour LCD8″ T ouch screen
  • Maximum power : 12 W
  • Configuration of the laser probe : Integral connection with the machine
  • Emmision wavelength laser diode : 810+980 nm
  • Laser classification : 4
  • DNRO(m) : 2,986
  • Emmision frequency : 100 – 10.000 Hz
  • Pulsed mode : 10 – 100%
  • Classification according to-
  • Directive 93/42/EEC : IIB
  • Output channels : 1
  • Insulation class/part applied inaccordance with EN60601-1 : I/BF Type
  • Stored protocols:32Storable programson the internal memory : 200
  • Storable programs on the USB : 4 GB
  • Weight : 4,90 Kg
  • Size : 39 x 17,5 x 28 cm

HighPowerLaser_Vikare 4W

1

WHY TO CHOOSE VIKARE
ViKare is designed as power laser that operates with a single wavelength: 940 nm. Making the most of the peak power from the two available models, you can provide up to 8W of power, performing a strong regeneration action in chronic diseases, speeding up the process of resolution of inflammation and oedema in the acuteillness, as well as the rapid resolution of pain syndromes in joints, muscles, and soft tissues.

TECHNICAL SPECIFICATION:

  • Power supply : 230 Vca, 50-60 Hz ± 10%
  • Maximum main power absoption : 70VA
  • Double delay type (T) mains : 230 V ac 630mA-T-5×20 mm
  • Backlit LCd display to view and check theoperating parameters : Graphic colour LCD6″ T ouch screen
  • Maximum power:4 W
  • Configuration of the laser probe : Integral connection with the machine
  • Emmision wavelength laser diode : 940 nm
  • Laser classification : 4
  • DNRO(m) : 1,251
  • Emmision frequency : 100 – 10.000 Hz
  • Pulsed mode : 10 – 100%
  • Classification according toDirective 93/42/EEC : IIB
  • Output channels : 1
  • Insulation class/part appliedin accordance with EN60601-1 : I/BF
  • TypeStored protocols : 32
  • Storable programs on the internal memory : 200
  • Storable programs on the smart card : 200
  • Weight : 4,65 Kg
  • Size : 39 x 17,5 x 28 cm

HighPowerLaser_Vikare 8W

1

WHY TO CHOOSE VIKARE
ViKare is designed as power laser that operates with a single wavelength: 940 nm. Making the most of the peak power from the two available models, you can provide up to 8W of power, performing a strong regeneration action in chronic diseases, speeding up the process of resolution of inflammation and oedema in the acuteillness, as well as the rapid resolution of pain syndromes in joints, muscles, and soft tissues.

TECHNICAL SPECIFICATION:

  • Power supply : 230 Vca, 50-60 Hz ± 10%
  • Maximum main power absoption : 70VA
  • Double delay type (T) mains : 230 V ac 630mA-T-5×20 mm
  • Backlit LCd display to view and checkthe operating parameters : Graphic colour LCD6″ T ouch screen
  • Maximum power : 8 W
  • Configuration of the laser probe : Integral connection with the machine
  • Emmision wavelength laser diode : 940 nm
  • Laser classification : 4
  • DNRO(m) : 1,721
  • Emmision frequency : 100 – 10.000 Hz
  • Pulsed mode : 10 – 100%
  • Classification according toDirective 93/42/EEC : IIB
  • Output channels : 1
  • Insulation class/part applied inaccordance with EN60601-1 : I/BF Type
  • Stored protocols : 32
  • Storable programs on the internal memory : 200
  • Storable programs on the smart card : 200
  • Weight : 4,65 Kg
  • Size : 39 x 17,5 x 28 cm